XRW-300C熱變形、維卡軟化點(diǎn)溫度測(cè)定儀
一、熱變形、維卡軟化點(diǎn)溫度測(cè)定儀產(chǎn) 品 詳 細(xì) 介 紹:
主要用于高分子材料(如塑料、橡膠、尼龍、電絕緣材料等)的熱變形及維卡軟化點(diǎn)溫度的測(cè)定。適用于大專院校,科研單位及產(chǎn)品質(zhì)量監(jiān)督檢驗(yàn)單位。該機(jī)采用具有Windows 98、Windows2000或WindowsXP中文操作界面,配控制軟件,在試驗(yàn)過(guò)程中,可以時(shí)實(shí)監(jiān)控試驗(yàn)溫度、試驗(yàn)變形量的曲線走向,并動(dòng)態(tài)地時(shí)實(shí)繪制溫度、變形量的曲線,實(shí)現(xiàn)歷史存盤(pán),打印試驗(yàn)報(bào)告,以便今后隨時(shí)查詢以前的試驗(yàn)數(shù)據(jù),進(jìn)行各種實(shí)驗(yàn)數(shù)據(jù)的對(duì)比研究,是一種智能化的測(cè)試儀器,當(dāng)用鼠標(biāo)點(diǎn)擊形變——溫度曲線的任何一處時(shí),界面會(huì)自動(dòng)顯示該處的變形量及溫度值。
熱變形、維卡軟化點(diǎn)溫度測(cè)定儀為立式柜結(jié)構(gòu),恒溫介質(zhì)箱內(nèi)采用45o雙螺旋自動(dòng)攪拌系統(tǒng),油箱具有特殊結(jié)構(gòu),溫度均勻性好,精度保持±0.1℃。并采用*的可控硅控制溫度,位移傳感器具有精調(diào)、微調(diào)雙調(diào)整方式,具有急停開(kāi)關(guān),后控制面版為帶鎖的門(mén)式結(jié)構(gòu),機(jī)器檢修、維修方便,升降系統(tǒng)為一體機(jī)型,減少噪音。故此,介質(zhì)的溫度梯度小,恒溫均勻,當(dāng)試驗(yàn)溫度達(dá)到上限設(shè)定溫度時(shí)自動(dòng)停止加熱,試驗(yàn)架具有自動(dòng)升降功能,操作簡(jiǎn)單,在同類機(jī)型中具有優(yōu)良的性能價(jià)格比。
二、符合標(biāo)準(zhǔn):
GB/T 1633-2000維卡軟化溫度(VST)的測(cè)定
GB/T 1634.1-2004塑料 負(fù)荷變形溫度測(cè)定(通用試驗(yàn)方法)
GB/T 1634.2-2004塑料 負(fù)荷變形溫度測(cè)定(塑料、硬橡膠和長(zhǎng)纖維增強(qiáng)復(fù)合材料)
GB/T 1634.3-2004塑料 負(fù)荷變形溫度測(cè)定(高強(qiáng)度熱固性層壓材料)
GB/T 8802-2001 熱塑性塑料管材、管件維卡軟化溫度的測(cè)定
ISO 75-1:2013 塑料 - 溫度變形,負(fù)荷 - 第1部分:通用試驗(yàn)方法
ISO 75-2-2013 塑料.載荷下?lián)锨鷾囟鹊臏y(cè)定.第2部分:塑料和硬橡膠
ISO 75-3-2013塑料.載荷下?lián)锨鷾囟鹊臏y(cè)定.第3部分高強(qiáng)度熱固性疊層板和長(zhǎng)纖維增強(qiáng)塑料
ISO75-1-04塑料載荷下?lián)锨鷾囟鹊臏y(cè)定第1部分一般試驗(yàn)方法、
ISO 2507-1-2017熱塑性塑料管和配件.維卡(vicat)軟化溫度.第1部分_一般試驗(yàn)方法
ISO 306-2013 塑料 熱塑塑料 維卡(VICAT)軟化溫度的測(cè)定
ASTM D1525 - 17e1Standard Test Method for Vicat Softening Temperature of Plastics
ASTM D648 - 16 Standard Test Method for Deflection Temperature of Plastics Under Flexural Load in the Edgewise Position
三、維卡(VST)定儀:
把試樣放在液體介質(zhì)或加熱箱中,在等速升溫條件下測(cè)定標(biāo)準(zhǔn)壓針在(50±1)N力的作用下,壓入從管材或管件上切取的試樣內(nèi)1mm時(shí)的溫度。
標(biāo)準(zhǔn)試樣以平放(優(yōu)選)或側(cè)立方式承受三點(diǎn)彎曲恒定負(fù)荷,使其產(chǎn)生GB/T 1634相關(guān)部分規(guī)定的其中一種彎曲應(yīng)力,在勻速升溫條件下,測(cè)量達(dá)到與規(guī)定的彎曲應(yīng)變?cè)隽肯鄬?duì)應(yīng)的標(biāo)準(zhǔn)撓度時(shí)的溫度。
側(cè)立:分“平放”與“側(cè)立”兩種,并明確指出,優(yōu)選平放方式,側(cè)立方式僅是備選,并將被撤銷。
跨度:支座與試樣兩條接觸線之間距離,由一種(100mm)改為兩種64mm(平放)和100mm(側(cè)立),并規(guī)定了容差要求即跨度L應(yīng)為(100±1)mm,跨度L為(64±1)mm。
負(fù)荷變形溫度的三種方法
A法:1.80Mpa彎曲應(yīng)力
B法:0.45MPa彎曲應(yīng)力
C法:8.00MPa彎曲應(yīng)力
四、主要性能指標(biāo):
熱變形、維卡軟化點(diǎn)溫度測(cè)定儀 | |
試樣架提取方式 | 自動(dòng)升降 |
控制方式 | 單片機(jī)和PC機(jī)分布式控制系統(tǒng) |
控溫范圍 | 室溫~300℃ |
升溫速率 | A速度:5±0.5℃/6min;B 速度:12±1.0℃/6min。 |
溫度準(zhǔn)確度 | ±0.5℃ |
溫度測(cè)量點(diǎn) | 1個(gè) |
試樣工位 | 3工位 |
變形分辨率 | 0.001mm |
變形測(cè)量范圍 | 0~10mm |
試樣支承跨距 | 64mm、100mm(美標(biāo)可調(diào)節(jié)尺寸) |
變形測(cè)量準(zhǔn)確度 | 0.005mm |
加熱介質(zhì) | 甲基硅油;閃點(diǎn)300℃以上、200厘斯以下(客戶自備) |
冷卻方法 | 150℃以上自然冷卻,150℃以下水冷或自然冷卻; |
儀器尺寸 | 600mm×600mm×1400mm |
所需空間 | 前后1m,左右0.6m |
電源 | 4500VA 220VAC 50H |
五、設(shè)備標(biāo)準(zhǔn)配置:
1、主機(jī) 一臺(tái)
2、數(shù)顯千分表 三個(gè)
3、試樣架 三個(gè)
4、熱變形壓頭 三個(gè)
5、維卡壓針三個(gè)
6、PC軟件 一套
7、砝碼一套
8、一個(gè)電源線 一根
9、信號(hào)線 一根
10、《產(chǎn)品用戶手冊(cè)》一套
11、試驗(yàn)應(yīng)用軟件一套(升級(jí))
可選配件:
1、品牌臺(tái)式電腦,含主機(jī)、液晶顯示器、鍵盤(pán)、光電鼠標(biāo)
2、品牌彩色噴墨打印機(jī)
備注:用戶需備有冷卻水源, 自備甲基硅油。
XRW-300C Thermal Deformation and Vicat Softening Point Temperature Measuring Instrument
The products of thermal deformation and Vicat softening point temperature tester are introduced in detail.
It is mainly used for the determination of thermal deformation and Vicat softening point temperature of polymer materials (such as plastics, rubber, nylon, electrical insulating materials, etc.). It is suitable for colleges and universities, scientific research units and product quality supervision and inspection units. This machine adopts Windows 98, Windows 2000 or Windows XP Chinese operation interface and control software. During the test process, it can real-time monitor the curve trend of test temperature and test deformation, and dynamically draw the curve of temperature and deformation in real time, so as to realize the historical storage and print the test report, so as to query the previous test data at any time in the future and carry out various experimental data. The comparative study is a highly intelligent testing instrument. When the mouse clicks on any part of the deformation-temperature curve, the interface will automatically display the deformation and temperature value.
The temperature tester for thermal deformation and Vicat softening point is a vertical cabinet structure. 45o double helix automatic stirring system is used in the constant temperature medium box. The oil tank has a special structure, good temperature uniformity, and high accuracy (+0.1 C). It adopts advanced thyristor to control temperature, displacement sensor has fine-tuning and fine-tuning double-tuning mode, has emergency stop switch, and the rear control panel is door-type structure with locks. It is convenient for machine maintenance and maintenance, and the lifting system is integrated into one model to reduce noise. Therefore, the temperature gradient of the medium is small and the constant temperature is uniform. When the test temperature reaches the upper set temperature, the heating stops automatically. The test stand has the function of automatic lifting and lowering. It is easy to operate and has excellent performance-price ratio in the same type of machine.
Thermal Deformation and Vicat Softening Point Temperature Measuring Instrument meets the standards:
Determination of Vicat Softening Temperature (VST) of GB/T 1633-2000
GB/T 1634.1-2004 Plastic Load Deformation Temperature Measurement (General Test Method)
Measurement of Plastic Load Deformation Temperature (Plastics, Hard Rubber and Long Fiber Reinforced Composites) GB/T 1634.2-2004
Measurement of Load Deformation Temperature of Plastics GB/T 1634.3-2004 (High Strength Thermosetting Laminated Materials)
Measurement of Vicat Softening Temperature of Thermoplastic Pipes and Fittings GB/T 8802-2001
ISO 75-1:2013 Plastics - Temperature Deformation, Load - Part 1: General Test Method
ISO 75-2-2013 Plastics - Determination of Flexural Temperature under Loading - Part 2: Plastics and Hard Rubber
ISO 75-3-2013 Plastics - Determination of Flexural Temperature under Loading - Part 3 High Strength Thermosetting Laminated Plates and Long Fiber Reinforced Plastics
ISO75-1-04 Determination of Flexural Temperature under Plastic Loading Part 1 General Test Method,
ISO 2507-1-1995 Thermoplastic Pipes and Accessories - Vicat Softening Temperature - Part 1 - General Test Method
Measurement of Softening Temperature of ISO 306-2013 Plastic Thermoplastic Vicat
ASTM D1525 - 17e1 Standard Test Method for Vicat Softening Temperature of Plastics
ASTM D648 - 16 Standard Test Method for Deflection Temperature of Plastics Under Flexural Load in the Edgewise Position
Vika (VST) tester: Put the sample in liquid medium or heating box, and measure the temperature of standard pressure needle under the action of (50 + 1) N force under the condition of constant temperature rise, when it is pressed into the sample cut from the pipe or fittings for 1 mm.
Standard specimens are subjected to constant load of three-point bending in a flat (preferred) or side-cubic manner, which results in one of the bending stresses specified in the relevant parts of GB/T 1634. Under uniform heating conditions, the temperature at which the standard deflection corresponding to the specified bending strain increment is measured.
Side-up: There are two kinds of "flat" and "side-up", and it is clearly pointed out that the side-cube is only an alternative and will be cancelled.
Span: The distance between the two contact lines of the bearing and the specimen is changed from one (100 mm) to two (64 mm) and 100 mm (lateral). The tolerance requirement is that the span L should be (100 + 1) mm and the span L should be (64 + 1) mm.
Three Methods of Load Deformation Temperature
Method A: 1.80 Mpa bending stress
Method B: Bending stress of 0.45 MPa
C method: 8.00MPa bending stress
The main performance indexes of the instrument for measuring thermal deformation and Vicat softening point temperature are as follows:
Temperature control range: room temperature - 300 C
Heating rate: 120 C/h, 50 C/h
Maximum temperature measurement error: +0.001 C
Maximum Temperature Control Error: +12 C/6 min (Thermal Deformation Test)
Five degrees Celsius/six minutes (Vicat test)
Vicat variable deflection: 1mm
Maximum Deformation Measurement Error: +0.001 mm
Sample holder number: 3
1
Heating medium: methyl silicone oil (below 200 centimeters, flash point above 300 C)
Maximum heating power: 5 kW
Cooling mode: natural cooling above 150 C, water cooling below 150 C or natural cooling. It has the function of temperature upper limit protection.
Main power supply: 220V + 10%, 15A, 50HZ;
A Set of Test Application Software for Chinese Operating System of Thermal Deformation and Vicat Softening Point Thermometer
Standard Configuration of Equipment for Thermal Deformation and Vicat Softening Point Temperature Measuring Instrument:
Three test stand spans are divided into two kinds of 64mm and 100mm arbitrarily selected test modes.
Deformation Error of Three Displacement Sensors (+0.001 mm)
Measuring error of temperature sensor imported from USA (+0.1 C)
Three arc radii of hot deformation indenter are R3
Vica test pin with 3 cross-sectional areas of 1 mm
Weight of Thermal Deformation and Vicat Softening Point Temperature Measuring Instrument