污水處理設(shè)備 污泥處理設(shè)備 水處理過濾器 軟化水設(shè)備/除鹽設(shè)備 純凈水設(shè)備 消毒設(shè)備|加藥設(shè)備 供水/儲水/集水/排水/輔助 水處理膜 過濾器濾芯 水處理濾料 水處理劑 水處理填料 其它水處理設(shè)備
上海銳一環(huán)??萍加邢薰?b class="member-infor">
參 考 價 | 面議 |
產(chǎn)品型號
品 牌
廠商性質(zhì)經(jīng)銷商
所 在 地
聯(lián)系方式:蔡磊查看聯(lián)系方式
更新時間:2022-04-18 10:00:09瀏覽次數(shù):170次
聯(lián)系我時,請告知來自 環(huán)保在線Vertrel™SMTspecialtyfluidChemoursVertrel™SMTspecialtyfluidisaproprietaryazeotropeofVertrel™XFwithtrans-1,2dichloroethyleneandmethanol
Vertrel™ SMT specialty fluid Chemours Vertrel™ SMT specialty fluid is a proprietary azeotrope of Vertrel™ XF with trans-1,2 dichloroethylene and methanol. It is ideal for use in a vapor degreaser with solvency power for cleaning ionic soils and flux residues from electronic assemblies. Vertrel™ SMT is widely used for the following applications: Compatibility and Soils Vertrel™ SMT is compatible with most plastics and elastomers, and can be used to clean a wide variety of soils including flux residue, cutting oils, gear oils, heavy greases, hydraulic oils, stamping oils, synthetic oils, vacuum oils, waxes, and mineral oils. Vertrel™ has zero ozone-depletion potential. It is used extensively to replace CFC-113, methyl chloroform, hydrochlorofluorocarbons (HCFCs), and perfluorocarbons (PFCs) in several applications. Vertrel™ SMT exhibits no closed-cup flash point in accordance with the Pensky-Martens Closed Cup Tester (ASTM D-93) and is not classified as a flammable liquid by NFPA or DOT. However, the product does exhibit vapor flammability limits in air. Users should clear equipment of all vapors and liquids before performing any maintenance operations that may result in an ignition source. 杜邦Vertrel SMT 技術(shù)文檔支持下載
Applications
Defluxing
Medium and Heavy Soil Removal
Light Soil Removal
Silicone Deposition and Tube Swelling
Precision Cleaning
Environmental Properties
Vertrel™ SMT has been accepted by the U.S. Environmental Protection Agency (EPA) under the Significant New Alternatives Policy (SNAP) program, as a substitute for ozone-depleting substances. The methanol component of Vertrel™ SMT is considered a hazardous air pollutant (HAP) and, therefore, subject to NESHAP regulations. Methanol is included in the SARA Title III Section 313 list of toxic chemicals, and is subject to SARA Title III (EPCRA) reporting requirements.
The components of Vertrel™ SMT are listed in the TSCA inventory. One component, HFC-43-10mee, is subject to the Significant New Use Rule (SNUR) and should be used only in the applications indicated in the Vertrel™ SMT MSDS regulatory section.
Flammability and Toxicity
Flash point data and limits of flammability in air provide the user with additional information that should be used as elements of a fire risk assessment and to determine guidelines for safe handling of volatile chemicals. Users should ensure compliance with NFPA standards and local fire codes.
Acute toxicity studies show that Vertrel™ SMT has low toxicity. It could pose a slight skin and eye irritation and has low inhalation toxicity. For exposure limits please refer to the Vertrel™ SMT brochure.
您感興趣的產(chǎn)品PRODUCTS YOU ARE INTERESTED IN
環(huán)保在線 設(shè)計制作,未經(jīng)允許翻錄必究 .? ? ?
請輸入賬號
請輸入密碼
請輸驗證碼
請輸入你感興趣的產(chǎn)品
請簡單描述您的需求
請選擇省份
聯(lián)系方式
上海銳一環(huán)??萍加邢薰?/p>