廢紙液壓打包機(又稱作廢紙打包機,垃圾打包機,塑料打包機,立式打包機,小型打包機,紙皮打包機)液壓打包機用 途: 本機適用于廢紙、邊角布料、廢舊塑料薄膜,廢紙、紙邊、服裝、布匹、廢海綿、魚網(wǎng)、廢舊塑膠、分檢垃圾、麥草等廢品壓制打包和棉、紗、布、羊毛、毛球等松散物的壓縮打包,包塊外形尺寸統(tǒng)一整齊、比重大、密度高??s小體積,便于倉儲和運輸給,給客戶物資的倉儲和運輸帶來了極大的方便和可觀的經(jīng)濟效益。適合于出口產(chǎn)品集裝箱裝運.
60噸立式雙缸廢紙液壓打包機
配用動力:11KW, 60 tons of vertical double cylinder hydraulic baler
Waste paper baler,
Equipped with power: 11KW,
Taiwan when the output: 3-5 mass,
Package weight: 200-300KG,
Cylinder: Φ150 * 2,
Easy to operate, the machine uses 46 # or 68 # hydraulic oil, the amount of 90kg hydraulic oil,
Connected to the power after packaging, dedicated to all light foam, loose material packaging. It can be used in cotton, wool, waste paper, waste paper box, waste paperboard, yarn, plastic, cloth, woven bag, knitted cashmere, hemp, sack, top, hair ball, cocoon, silk, hops, , Waste plastic bags and all the light foam, loose material. It is a necessary production tool for cotton producing areas, textile enterprises, supermarkets, garment factories, waste materials recycling industry and other light industrial enterprises.
60 tons of double cylinder hydraulic baler
Model: 60
Nominal pressure master cylinder KN: 600
Liquid maximum working pressure MPa: 15
Box size 900mm long, 650mm wide, high: 1400mm
Package Size: Length 900mm * Width: 650 * Height: (500-1000) mm
Mass density kg / m3: ≥ 500
Single cycle time S: 36
Motor power KW: 11
Cylinder travel: 1000MM
Machine dimensions mm: Length 1550 * Width 1100 * Height 3200.
Machine weight kg; 2200.
Hydraulic baler instructions
First, the installation steps
1, the machine must be placed on the concrete, the basic depending on the local situation.
2, check the bottom of the fuel tank is closed, to determine the closure and then open the top of the tank filling port seal.
Injection of about 90KG, 68 # hydraulic oil, hydraulic oil row number as the local temperature and the use of standards. [Note! If the model is above 60T, the new machine must be filled with oil twice, the first time into the hydraulic oil height to the top of the dipstick (blue line). Press the press down to the bottom and then add the hydraulic oil to the bottom of the dipstick (red border) see the operating instructions in detail 4]
3, the installation of the local power cord, voltage and frequency depending on the local power supply decision, (Note! Motor and electrical parts of the voltage and frequency of customer orders have been ordered to install the machine installed) conventional three-phase four-wire system, three With the power cord, respectively, into the electrical phase of the corresponding three wiring bits (Figure 7 left) and the other for the ground leakage protection line, should be exposed to the body exposed metal surface to prevent electrical leakage wounding.
Second, the operation method:
1, access to power: the air box inside the air switch (the main switch) to close, first check the three-phase power supply voltage is normal, (with a meter or probe pen test) to close the electrical phase door, see the power of the door surface red power Whether the indicator light is on.
2, start the motor: the manual valve handle (pay Figure 3) down to the bottom (the body with the operation icon), and then press the button NO button (Figure 5 lower right), (Note: if installed There are emergency stop switch models, please put the emergency stop switch in the direction of the arrow, the emergency stop switch can pop up), (Figure 5 on the right) as normal under the motor start.
3, check the motor steering: (Figure 8) After the motor starts, manual valve handle in the lowest position, such as the pressure plate can not move down. In this case, you must immediately check whether the direction of rotation of the motor is correct and the direction of rotation of the motor must be in the direction indicated by the arrow. If the motor turns to the opposite when the machine can not be used normally, then the manual valve handle should be pulled up to the mid-range position. Then press the stop button OFF (or the emergency stop switch is pressed) to stop the motor from running. Cut off the total input power, the three-phase power cord which can be connected to the two-phase line. And then press operations 1 and 2 to re-operate, (Note! Must determine whether the motor steering direction is consistent with the arrow.)
4, into the fuel of the key: When the pressure plate down the normal move, the pressure plate in the first move, the movement speed is not uniform. To be pressed to move to the bottom or move suddenly stop or move the noise increases, in which case the manual valve should be pulled up to the middle of the handle, stop the switch OFF or emergency stop switch, stop the motor run. And then carefully check the tank oil storage is sufficient, such as oil at the end of the fuel tank height of half, to prove that the amount of oil, then again should be injected into the tank appropriate hydraulic oil. The amount of fuel should be added to the bottom line of the oil level (red line) can be.