亚洲国产精品二区久久,日本美女后入式午夜视频在线观看,国产污视频在线观看,欧美日韩国产精品中文字幕在线观看

行業(yè)產(chǎn)品

  • 行業(yè)產(chǎn)品

上海榮計達儀器科技有限公司


當(dāng)前位置:上海榮計達儀器科技有限公司>>節(jié)能建材檢測儀器>>YZS數(shù)顯氧指數(shù)測定儀

YZS數(shù)顯氧指數(shù)測定儀

返回列表頁
參  考  價面議
具體成交價以合同協(xié)議為準(zhǔn)

產(chǎn)品型號YZS

品       牌

廠商性質(zhì)其他

所  在  地上海市

聯(lián)系方式:王林查看聯(lián)系方式

更新時間:2023-08-31 18:27:05瀏覽次數(shù):173次

聯(lián)系我時,請告知來自 環(huán)保在線

經(jīng)營模式:其他

商鋪產(chǎn)品:254條

所在地區(qū):

聯(lián)系人:王林

產(chǎn)品簡介

氧指數(shù)分析儀是檢測儀器,用于均質(zhì)材料、層壓材料、泡沫材料、軟片和薄膜材料,在常溫常壓下,氧、氮混合氣體中調(diào)節(jié)剛好維持試樣燃燒的氧濃度。本機采用電機及調(diào)速系統(tǒng)一體化結(jié)構(gòu)驅(qū)動減速機,經(jīng)減速后帶動絲杠進行加載。

詳細(xì)介紹

YZS數(shù)顯氧指數(shù)測定儀是檢測儀器,用于均質(zhì)材料、層壓材料、泡沫材料、軟片和薄膜材料,在常溫常壓下,氧、氮混合氣體中調(diào)節(jié)剛好維持試樣燃燒的氧濃度。本機采用電機及調(diào)速系統(tǒng)一體化結(jié)構(gòu)驅(qū)動減速機,經(jīng)減速后帶動絲杠進行加載。電氣部分包括試驗力測量系統(tǒng)和變形測量系統(tǒng)。并具有過載保護、位移控制等功能。設(shè)計簡單,使用方便,性能穩(wěn)定安全。

The oxygen index analyzer is a testing instrument for homogeneous materials, laminated materials, foam materials, films and film materials. At normal temperature and pressure, the oxygen and nitrogen mixtures are adjusted to just maintain the oxygen concentration of the sample. This machine adopts the integrated structure of motor and speed control system to drive the reducer, and after the deceleration, the lead screw is loaded for loading. The electrical part includes a test force measurement system and a deformation measurement system. And has overload protection, displacement control and other functions. Simple design, easy to use, stable and safe performance.


YZS數(shù)顯氧指數(shù)測定儀符合標(biāo)準(zhǔn):

依據(jù)《EN ISO 4589-2:2006-06室溫氧指數(shù)測試》及《GBT 2406-1993 塑料燃燒性能試驗方法 氧指數(shù)法》《GBT 8924-2005 纖維增強塑料燃燒性能試驗方法氧指數(shù)法等要求生產(chǎn)。

The oxygen index analyzer meets the standards:

It is produced according to the requirements of "EN ISO 4589-2: 2006-06 Room Temperature Oxygen Index Test" and "GBT 2406-1993 Test Method for Burning Performance of Plastics.


YZS數(shù)顯氧指數(shù)測定儀技術(shù)參數(shù):

★測量范圍:0-A、/02

★分辨率:0.1%、/02

★測量精度:(±0.4%)、/02

★響應(yīng)時間:

★數(shù)顯精度:0.1%±1個字

★輸出漂移:<5%/年

★秒表:精度0.5s

★外形尺寸約:360×250×530mm

★保修期:發(fā)貨后12個月

★儀器的工作條件:

★環(huán)境溫度:-10℃-40℃

★相對濕度: ≤85%

★使用氣體:GB3863工業(yè)用氣態(tài)氧;GB3864工業(yè)用氣態(tài)氮;兩瓶氣體均要調(diào)壓器(用戶自配)

★輸入壓力:(0.25-0.4) Mpa

★工作壓力:O.lMpa

Technical parameters of oxygen index analyzer:

★ Measuring range: 0-A, / 02

★ Resolution: 0.1%, / 02

★ Measurement accuracy: (± 0.4%), / 02

★ Response time:

★ Digital display accuracy: 0.1% ± 1 character

★ Output drift: <5% / year

★ Stopwatch: 0.5s accuracy

★ Approximate dimensions: 360 × 250 × 530mm

★ Warranty period: 12 months after delivery

★ Working conditions of the instrument:

★ Ambient temperature: -10 ℃ -40 ℃

★ Relative humidity: ≤85%

★ Gas used: GB3863 industrial gaseous oxygen; GB3864 industrial gaseous nitrogen; both bottles of gas need pressure regulator (user-supplied)

★ Input pressure: (0.25-0.4) Mpa

★ Working pressure: O.lMpa


YZS數(shù)顯氧指數(shù)測定儀操作方法:

★檢查氣路,確定各部分連接無誤,無漏氣現(xiàn)象。

★確定實驗開始時的氧濃度:根據(jù)經(jīng)驗或試樣在空氣中點燃的情況,估計開始實驗時的氧濃度。如試樣在空氣中迅速燃燒,則開始實驗時的氧濃度為18%左右;如在空氣中緩慢燃燒或時斷時續(xù),則為21%左右;在空氣中離開點火源即馬上熄滅,則至少為25%。根據(jù)經(jīng)驗,確定該地板革氧指數(shù)測定實驗初始氧濃度為26%。氧濃度確定后,在混合氣體的總流量為10l/min的條件下,便可確定氧氣、氮氣的流量。例如,若氧濃度為26%,則氧氣、氮氣的流量分別為2.5l/min和7.5l/min。

★安裝試樣:將試樣夾在夾具上,垂直地安裝在燃燒筒的**位置上(注意要劃50mm標(biāo)線),保證試樣頂端低于燃燒筒頂端至少100mm,罩上燃燒筒(注意燃燒筒要輕拿輕放)。

★通氣并調(diào)節(jié)流量:開啟氧、氮氣鋼瓶閥門,調(diào)節(jié)減壓閥壓力為0.2~0.3MPa(由教員完成),然后開啟氮氣和氧氣管道閥門(在儀器后面標(biāo)注有紅線的管路為氧氣,另一路則為氮氣,應(yīng)注意:先開氮氣,后開氧氣,且閥門不宜開得過大),然后調(diào)節(jié)穩(wěn)壓閥,儀器壓力表指示壓力為0.1±0.01MPa,并保持該壓力(禁止使用過高氣壓)。調(diào)節(jié)流量調(diào)節(jié)閥,通過轉(zhuǎn)子流量計讀取數(shù)據(jù)(應(yīng)讀取浮子上沿所對應(yīng)的刻度),得到穩(wěn)定流速的氧、氮氣流。應(yīng)注意:在調(diào)節(jié)氧氣、氮氣濃度后,必須用調(diào)節(jié)好流量的氧氮混合氣流沖洗燃燒筒至少30s(排出燃燒筒內(nèi)的空氣)。

★點燃試樣:用點火器從試樣的頂部中間點燃,勿使火焰碰到試樣的棱邊和側(cè)表面。在確認(rèn)試樣頂端全部著火后,立即移去點火器,開始計時或觀察試樣燒掉的長度。點燃試樣時,火焰作用的時間A長為30s,若在30s內(nèi)不能點燃,則應(yīng)增大氧濃度,繼續(xù)點燃,直至30s內(nèi)點燃為止。

★確定臨界氧濃度的大致范圍:點燃試樣后,立即開始記時,觀察試樣的燃燒長度及燃燒行為。若燃燒終止,但在1s內(nèi)又自發(fā)再燃,則繼續(xù)觀察和記時。如果試樣的燃燒時間超過3min,或燃燒長度超過50mm(滿足其中之一),說明氧的濃度太高,必須降低,此時記錄實驗現(xiàn)象記“×",如試樣燃燒在3min和50mm之前熄滅,說明氧的濃度太低,需提高氧濃度,此時記錄實驗現(xiàn)象記“Ο"。如此在氧的體積百分濃度的整數(shù)位上尋找這樣相鄰的四個點,要求這四個點處的燃燒現(xiàn)象為“ΟΟ××"。例如若氧濃度為26%時,燒過50mm的刻度線,則氧過量,記為“×",下一步調(diào)低氧濃度,在25%做**次,判斷是否為氧過量,直到找到相鄰的四個點為氧不足、氧不足、氧過量、氧過量,此范圍即為所確定的臨界氧濃度的大致范圍。

★在上述測試范圍內(nèi),縮小步長,從低到高,氧濃度每升高0.4%重復(fù)一次以上測試,觀察現(xiàn)象,并記錄。

★根據(jù)上述測試結(jié)果確定氧指數(shù)OI。

Operation method of oxygen index analyzer:

★ Check the gas path to make sure that all parts are connected correctly and there is no air leakage.

★ Determine the oxygen concentration at the beginning of the experiment: Based on experience or the ignition of the sample in the air, estimate the oxygen concentration at the beginning of the experiment. If the sample burns rapidly in the air, the oxygen concentration at the beginning of the experiment is about 18%; if it burns slowly or intermittently in the air, it is about 21%; when it leaves the ignition source in the air and immediately goes out, At least 25%. According to experience, it is determined that the initial oxygen concentration of the floor leather oxygen index measurement experiment is 26%. After the oxygen concentration is determined, the flow rate of oxygen and nitrogen can be determined under the condition that the total flow rate of the mixed gas is 10 l / min. For example, if the oxygen concentration is 26%, the flow rates of oxygen and nitrogen are 2.5 l / min and 7.5 l / min, respectively.

★ Install the sample: Clamp the sample on the fixture and install it vertically on the ** position of the combustion cylinder (note the 50mm mark) to ensure that the top of the sample is at least 100mm lower than the top of the combustion cylinder. Note that the burner should be handled gently.

Ventilation and flow adjustment: Open the oxygen and nitrogen cylinder valves, adjust the pressure reducing valve pressure to 0.2 to 0.3 MPa (completed by the instructor), and then open the nitrogen and oxygen pipeline valves (the pipeline marked with a red line on the back of the instrument is oxygen, and the other The other way is nitrogen, it should be noted that: first open nitrogen, then open oxygen, and the valve should not be opened too large), and then adjust the pressure regulator valve, the instrument pressure gauge indicates that the pressure is 0.1 ± 0.01MPa, and maintain this pressure (prohibited use High pressure). Adjust the flow control valve and read the data through the rotor flowmeter (the corresponding scale on the upper edge of the float should be read) to obtain a stable flow of oxygen and nitrogen. It should be noted that after adjusting the concentration of oxygen and nitrogen, the combustion cylinder must be flushed with the adjusted flow of oxygen-nitrogen mixed gas for at least 30s (exhaust the air in the combustion cylinder).

★ Ignite the sample: Use an igniter to ignite from the middle of the top of the sample. Do not let the flame hit the edges and side surfaces of the sample. After confirming that the top of the sample is on fire, remove the igniter immediately and start timing or observe the length of the sample burned out. When the sample is ignited, the flame action time A is 30s. If it cannot be ignited within 30s, increase the oxygen concentration and continue to ignite until it ignites within 30s.

★ Determine the approximate range of critical oxygen concentration: immediately after igniting the sample, start timing and observe the burning length and burning behavior of the sample. If the combustion is terminated, but spontaneously re-ignites within 1 s, continue observation and timing. If the burning time of the sample exceeds 3min, or the burning length exceeds 50mm (one of them is satisfied), it means that the oxygen concentration is too high and must be reduced. At this time, record the experimental phenomenon and record “×". For example, if the sample burns before 3min and 50mm When it is off, it means that the oxygen concentration is too low, and the oxygen concentration needs to be increased. At this time, the experimental phenomenon "0" is recorded. In this way, looking for such four adjacent points on the integer digits of the volume percentage concentration of oxygen, it is required that the combustion phenomenon at these four points is “0 ××". For example, if the oxygen concentration is 26% and the 50mm mark is burned, the excess oxygen will be marked as “×". Next, adjust the oxygen concentration to 25% and do it ** times to determine whether it is oxygen excess until the phase is found. The four adjacent points are oxygen deficiency, oxygen deficiency, oxygen excess, and oxygen excess, and this range is the approximate range of the determined critical oxygen concentration.

★ In the above test range, reduce the step size, from low to high, repeat the test more than once for every 0.4% increase in oxygen concentration, observe the phenomenon, and record.

★ Determine the oxygen index OI based on the above test results.


YZS數(shù)顯氧指數(shù)測定儀注意事項:

★本設(shè)備是試驗測試設(shè)備請不要將本設(shè)備用于規(guī)定試驗及料以外的目的。

試樣制作要精細(xì)、準(zhǔn)確,表面平整、光滑。

氧、氮氣流量調(diào)節(jié)要得當(dāng),壓力表指示處于正常位置,禁止使用過高氣壓,以防損壞設(shè)備。

流量計、玻璃筒為易碎品,實驗中謹(jǐn)防打碎。

★請完善安裝環(huán)境

請置于室溫下。濕度低的場所。(80%以下無結(jié)露)灰塵和塵埃少的場所。

★請按要求安裝試驗材料

按要求安裝試驗材料,否則可能出現(xiàn)A預(yù)期故障。

★進行配線和維護作業(yè)時,請務(wù)必關(guān)閉電源

為了防止在作業(yè)過程中機器失去控制而導(dǎo)致事故和觸電,請在進行作業(yè)前,務(wù)必先關(guān)閉電源。

★電源

關(guān)于本設(shè)備的電源,請注意以下事項。

原則上配電方式采用單相220V電源。

關(guān)于電源及電源工程,請與電氣工程人員或有同等知識的人士商量。

★電源線

請務(wù)必使用隨設(shè)備提供的電源線。發(fā)現(xiàn)電源線和電源插頭有異常情況時,請與本公司聯(lián)系。同我公司服務(wù)人員進行更換或指導(dǎo)更換。

★保險絲

為了防止火災(zāi)和內(nèi)部電路的破損等,請不要用規(guī)定以外的保險絲。更換保險絲時,請使用與原設(shè)備相同型號和形狀的保險絲。

★特別警告

警告應(yīng)注意所執(zhí)行的應(yīng)用、或條件均具有很高的危險性,可能導(dǎo)致人員受傷或甚至死亡。

為了防止意外傷害或死亡發(fā)生,在搬移和使用設(shè)備時,請務(wù)必先觀察清楚,然后再進行動作。

Note of oxygen index analyzer:

★ This equipment is a test equipment. Please do not use this equipment for purposes other than specified tests and materials.

The preparation of the sample should be fine and accurate, and the surface should be smooth and smooth.

The flow of oxygen and nitrogen must be properly adjusted. The pressure gauge indicates that it is in the normal position. It is forbidden to use excessively high pressure to prevent damage to the equipment.

The flowmeter and glass tube are fragile, so be careful not to break them during the experiment.

★ Please perfect the installation environment

Please leave it at room temperature. Places with low humidity. (No condensation below 80%) Place with little dust and dust.

★ Please install test materials as required

Install the test materials as required, otherwise A expected failure may occur.

★ Be sure to turn off the power when performing wiring and maintenance work

In order to prevent accidents and electric shock caused by the machine losing control during the work, please turn off the power before working.

★ Power

Regarding the power of this device, please note the following.

In principle, a single-phase 220V power supply is used for power distribution.

For power supply and power supply engineering, please consult with electrical engineering personnel or persons with equivalent knowledge.

★ Power cord

Be sure to use the power cord provided with the device. If you find anything abnormal with the power cord and plug, please contact us. Replace or instruct the replacement with our service personnel.

★ Fuse

To prevent fire, damage to internal circuits, etc., do not use fuses other than those specified. When replacing fuses, use fuses of the same type and shape as the original equipment.

★ Special warning

WARNING It should be noted that the application or condition being performed is highly dangerous and could result in injury or even death.

To prevent accidental injury or death, be sure to observe clearly when moving and using the equipment before moving.


YZS數(shù)顯氧指數(shù)測定儀裝箱清單:

★主機:1臺

★玻璃管:2根

★玻璃珠:1斤(放入燃燒柱內(nèi))

★尼龍管:1.2米f連接燃燒柱與主機)

★密封圈:若干

★試樣夾:l套

★金屬網(wǎng):1個(放入燃燒柱內(nèi))

★板手10-12:1把

★橡皮管:2根

★Ml0×1內(nèi)接頭螺釘:1顆(接燃燒柱內(nèi))

★Ml0×1接頭螺母:l顆(接主機)

★說明書:1份

★合格證:1張

★GB/T2406標(biāo)準(zhǔn):1份

Packing list of oxygen index analyzer

★ Host: 1

★ Glass tube: 2

★ Glass Beads: 1 kg (into the combustion column)

★ Nylon tube: 1.2m f connecting the combustion column and the host)

★ Seal ring: several

★ Sample holder: l set

★ Metal mesh: 1 (inside the combustion column)

★ Wrench 10-12: 1

★ rubber tube: 2

★ Ml0 × 1 inner joint screw: 1 (inside the combustion column)

★ Ml0 × 1 connector nut: 1 pc (connect to the host)

★ Instruction: 1 copy

★ Certificate of Conformity: 1

★ GB / T2406 standard: 1 copy



感興趣的產(chǎn)品PRODUCTS YOU ARE INTERESTED IN

環(huán)保在線 設(shè)計制作,未經(jīng)允許翻錄必究 .? ? ? Copyright(C)?2021 http://www.kytsldc.cn,All rights reserved.

以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),環(huán)保在線對此不承擔(dān)任何保證責(zé)任。 溫馨提示:為規(guī)避購買風(fēng)險,建議您在購買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復(fù)您~
久久免费观看归女高潮特黄-黄色av一本二本在线观看| 亚洲黑人欧美一区二区三区-亚洲一区二区三区免费视频播放| 国产欧美日本不卡精美视频-日本后入视频在线观看| 亚洲日本一区二区三区黄色电形-中文字幕乱码免费熟女| 人妻丝袜中文字幕在线视频-亚洲成av人片一区二区三区| 哦啊好大用力欧美视频-麻豆国产传媒片在线观看| 一级特黄大片亚洲高清-国产精品视频伊人久久| 国模自慰一区二区三区-日韩一级黄色片天天看| 黄片黄片在线免费观看-激情综合网激情五月俺也去| 91麻豆免费在线视频-欧美中文天堂在线观看| 欧洲精品一区二区三区中文字幕-91久久国产综合久久蜜月精品| 国产美女网站在线观看-国产精品亚洲综合网69| 国产剧情av中文字幕-五月婷婷在线手机视频| 丝袜美腿人妻连续中出-在线观看日韩三级视频| 久久精品国产亚洲av湖南-竹菊精品一区二区三区| 国产一级片久久免费看同-麻豆精品尤物一区二区青青| 亚洲欧美精品在线一区-99热国产在线手机精品99| 人妻少妇无乱码中文字幕-人成免费视频一区二区| 国产av一区二区三区日韩接吻-av网址在线播放网站| 天天干天天日天天射天天舔-精品香蕉视频官网在线观看| 青青草原免费国产在线视频-精品人妻乱码一区二区三区四区| 色噜噜噜噜一区二区三区-欧美最猛黑人做爰视频| 在线国产自偷自拍视频-蜜桃a∨噜噜一区二区三区| 亚洲女人黄色录像一区-日韩av电影在线免费看| 十九禁止观看无码视频-亚洲国产激情福利专区| 国产精品中出久久久蜜臀-久久久中国精品视频久久久| 国产亚洲欧美一区91-亚洲欧美一区二区在线| 亚洲另类熟女国产精品-懂色一区二区三区在线播放| 精品国产综合一区二区三区-蜜臀一区二区三区刺激视频| av一区免费在线观看-中文字幕日韩国产精品视频| 97一区二区三区在线-欧美护士性极品hd4k| 国产福利视频一区二区三区-日韩人妻中文视频精品| 亚洲另类自拍唯美另类-99国产精品兔免久久| 国产亚洲欧美一区91-亚洲欧美一区二区在线| 日本欧美在线视频观看-国产一区二区三区无码下载快播| 国产亚洲欧美一区91-亚洲欧美一区二区在线| 久久久国产精品电影片-精品孕妇人妻一区二区三区| 国产精品一区二区在线免费-久久精品国产亚洲av热明星| 色婷婷六月婷婷一区二区-91草草国产欧美在线观看| 色综合色综合久久综合频道-埃及艳后黄版在线观看| 韩漫一区二区在线观看-精品国产免费未成女一区二区三区|